Controlled explosion of the cooling towers 1 to 4 in Thierbach power station

Explosion of the four towers in one event

Client:
Thierbach/ Picture 1

Thierbach/ Picture 1

Biq GmbH

Project management TVF:

Region South/East

Time frame:

Begin: January 2006 End: August 2006

Job description:

  • Controlled explosion of the four cooling towers with a one second time lapse between each explosion
    Thierbach/ Picture 2

    Thierbach/ Picture 2

  • Preparation of the rubble with a heavy plant crusher and subsequent recycling
  • Clearance of the site

Special factors:

  • Completion of an evidence securing operation in a nearby catering building for the settlement of any eventual damage caused
  • Closing of the main road B48 by the police to create a safety zone

Quantity details:

  • Height of the cooling towers 90 metres
  • Diameter at the top 36.90 metres
    Thierbach/ Picture 3

    Thierbach/ Picture 3

  • Diameter at the base 32.80 metres
  • Total material 21,000 tons

Controlled explosion details:

  • Drilled holes and number of detonators 1,932
  • Fuse cable Dynacord 1,800 metres
  • Explosive Eurodyn 2000 175 kilograms
  • Creation of fall slots (pre determined breaking points) with a cable excavator
  • Attachment of circa 10,000 square metres of fleece matting and circa 3,000 square metres of wire netting to prevent flying grit